Skip to main content

HPE iLO

Overview

Motadata AIOps provides extensive monitoring capabilities for HPE iLO. Using SNMP (Simple Network Management Protocol), this integration collects and reports various metrics related to system health, including CPU and memory usage, hardware sensor statuses, power supply information, fan speeds, temperature readings, and physical drive conditions. This allows IT administrators to ensure optimal performance, detect potential issues early, and maintain a high level of operational reliability.

Prerequisites

Refer Adding network devices for monitoring to understand the prerequisites necessary for monitoring a network device.

List of Supported KPIs

NameDescriptionType
power.supply.sensorPower supply sensor data.String
power.supply.sensor.statusStatus of the power supply sensor.String
fan.sensorFan sensor data.String
fan.sensor.statusStatus of the fan sensor.String
memory.device.numberNumber identifying the memory device.Count
memory.device.capacity.bytesCapacity of the memory device in bytes.Count
memory.device.typeType of the memory device.String
memory.deviceMemory device data.String
memory.device.current.statusCurrent status of the memory device.String
power.supply.sensor.instanceInstance key for the power supply sensor.String
power.supply.sensor.chassis.numberChassis number for the power supply sensor.Count
power.supply.sensor.main.mill.voltsMain voltage in millivolts for the power supply sensor.Count
power.supply.sensor.capacity.used.mill.wattsCapacity used in milliwatts for the power supply sensor.Count
power.supply.sensor.modelModel of the power supply sensor.String
power.supply.sensor.serial.numberSerial number of the power supply sensor.String
power.supply.sensor.hardware.locationHardware location of the power supply sensor.String
physical.drivePhysical drive data.String
physical.drive.statusStatus of the physical drive.String
physical.drive.conditionCondition of the physical drive.String
physical.drive.capacity.bytesCapacity of the physical drive in bytes.Count
physical.drive.configuration.statusConfiguration status of the physical drive.String
physical.drive.typeType of the physical drive.String
temperature.sensorTemperature sensor data.String
temperature.sensor.system.locationSystem location of the temperature sensor.String
temperature.sensor.current.temperature.celsiusCurrent temperature in Celsius reported by the sensor.Count
temperature.sensor.conditionCondition of the temperature sensor.String
fan.sensor.chassis.numberChassis number for the fan sensor.Count
fan.sensor.system.locationSystem location of the fan sensor.String
fan.sensor.typeType of the fan sensor.String
fan.sensor.conditionCondition of the fan sensor.String
fan.sensor.current.speed.rpmCurrent speed of the fan in RPM.Count
processor.deviceProcessor device data.String
processor.device.statusStatus of the processor device.String
processor.device.coreNumber of cores in the processor device.Count
processor.device.serial.numberSerial number of the processor device.String
processor.device.max.speed.mhzMaximum speed of the processor in MHz.Count
interface.sent.discard.packetsNumber of discarded packets sent on the interfaceCount
interface.in.packetsNumber of incoming packets on the interfaceCount
interface.packetsNumber of packets on the interfaceCount
interface.error.packetsNumber of error packets on the interfaceCount
interface.sent.error.packetsNumber of error packets sent on the interfaceCount
interface.received.discard.packetsNumber of discarded packets received on the interfaceCount
interface.received.octetsNumber of octets received on the interfaceCount
interface.bit.typeBit type of the interfaceCount
statusStatus of the interfaceString
interface.out.packetsNumber of outgoing packets on the interfaceCount
interface.operational.statusOperational status of the interfaceString
interface.admin.statusAdmin status of the interfaceCount
interface.sent.octetsNumber of octets sent on the interfaceCount
interface.last.changeLast change of the interfaceString
interface.received.error.packetsNumber of error packets received on the interfaceCount
interface.discard.packetsNumber of discarded packets on the interfaceCount
ping.min.latency.msMinimum latency (in milliseconds) observed during pingCount
ping.received.packetsNumber of packets received during pingCount
ping.lost.packetsNumber of packets lost during pingCount
ping.max.latency.msMaximum latency (in milliseconds) observed during pingCount
object.targetTarget object identifierString
ping.sent.packetsNumber of packets sent during pingCount
ping.packet.lost.percentPercentage of packet loss during pingPercent
ping.latency.msAverage latency (in milliseconds) observed during pingCount
system.oidSystem Object IdentifierString
started.time.secUptime in Seconds for the monitorCount
started.timeUptime of the monitorString
object.nameName of the monitorString
system.locationLocation of the monitorString
system.descriptionDescription of the monitorString