Skip to main content

Arris Interactive

Overview

Valere Power UPS, the reliable and high-performance uninterruptible power supply solutions by Valere Power, seamlessly integrate with Motadata AIOps to provide comprehensive monitoring and management capabilities. With this integration, organizations gain real-time visibility into the performance and health of their Valere Power UPS devices. Monitor critical UPS metrics such as battery status, load levels, and input/output voltage to ensure continuous and reliable power protection.

Prerequisites

Refer Adding network devices for monitoring to understand the prerequisites necessary for monitoring a network device.

List of Supported KPIs

MetricsDescriptionType
ping.min.latency.msMinimum latency (in milliseconds) observed during pingCount
ping.received.packetsNumber of packets received during pingCount
ping.lost.packetsNumber of packets lost during pingCount
ping.max.latency.msMaximum latency (in milliseconds) observed during pingCount
object.targetTarget object identifierString
ping.sent.packetsNumber of packets sent during pingCount
ping.packet.lost.percentPercentage of packet loss during pingPercent
ping.latency.msAverage latency (in milliseconds) observed during pingCount
system.oidSystem Object IdentifierString
started.time.secUptime in Seconds for the monitorCount
started.timeUptime of the monitorString
object.nameName of the monitorString
system.locationLocation of the monitorString
system.descriptionDescription of the monitorString
correlation.metricsCorrelation metrics between network connectionsString
network.connection.tcp.connectionsNumber of TCP connectionsCount
network.connection.udp.connectionsNumber of UDP connectionsCount
network.connection.udp.error.segmentsNumber of UDP error segmentsCount
network.connection.tcp.error.segmentsNumber of TCP error segmentsCount
network.connection.tcp.retransmitted.segmentsNumber of TCP retransmitted segmentsCount
destination.ipDestination IP addressString
destination.portDestination port numberCount
network.connection.protocolProtocol used for network connectionCount
network.connection.stateState of the network connectionString
source.ipSource IP addressString
source.portSource port numberCount
interface.sent.discard.packetsNumber of discarded packets sent on the interfaceCount
interface.in.packetsNumber of incoming packets on the interfaceCount
interface.packetsNumber of packets on the interfaceCount
interface.error.packetsNumber of error packets on the interfaceCount
interface.sent.error.packetsNumber of error packets sent on the interfaceCount
interface.received.discard.packetsNumber of discarded packets received on the interfaceCount
interface.received.octetsNumber of octets received on the interfaceCount
interface.bit.typeBit type of the interfaceCount
statusStatus of the interfaceString
interface.out.packetsNumber of outgoing packets on the interfaceCount
interface.operational.statusOperational status of the interfaceString
interface.admin.statusAdmin status of the interfaceCount
interface.sent.octetsNumber of octets sent on the interfaceCount
interface.last.changeLast change of the interfaceString
interface.received.error.packetsNumber of error packets received on the interfaceCount
interface.discard.packetsNumber of discarded packets on the interfaceCount
started.timeUptime of the interfaceString
started.time.secUptime in seconds of the interfaceString
ups.loadThe load on the UPS (Uninterruptible Power Supply).percentage
ups.chargeThe charge level of the UPS battery.percentage
ups.input.line.voltageThe input line voltage of the UPS.count
ups.output.line.voltageThe output line voltage of the UPS.count
ups.output.currentThe current output of the UPS.count
ups.sensor.statusThe status of the UPS sensor.string
ups.sensor.communications.statusThe communication status of the UPS sensor.string
ups.battery.last.replace.dateThe date when the UPS battery was last replaced.string
ups.last.self.test.dateThe date of the last self-test performed on the UPS.string
ups.battery.statusThe status of the UPS battery.string
ups.battery.temperatureThe temperature of the UPS battery.count
ups.battery.replaceIndicates whether the UPS battery needs replacement.string
ups.input.voltageThe input voltage of the UPS.count
ups.external.batteries.infectedIndicates if external batteries are infected.string
ups.comm.statusThe communication status of the UPS.count
ups.reason.for.last.transferThe reason for the last transfer of power source.string
ups.battery.runtime.remainThe remaining runtime of the UPS battery.count
ups.output.voltageThe output voltage of the UPS.count
ups.battery.time.on.batteryThe time the UPS battery can last on battery power.count
ups.input.frequencyThe input frequency of the UPS.count
ups.output.statusThe status of the UPS output.string
ups.input.sourceThe source of input for the UPS.string
ups.time.remainingThe remaining time of the UPS.count
ups.battery.currentThe current of the UPS battery.count
ups.backup.time.remainingThe remaining backup time of the UPS.count
ups.output.loadThe load on the UPS output.percentage
ups.temperatureThe temperature of the UPS.count
ups.battery.power.consumedThe power consumed by the UPS battery.count
ups.number.transientsThe number of transients experienced by the UPS.count
ups.battery.voltageThe voltage of the UPS battery.count
ups.output.frequencyThe output frequency of the UPS.count
ups.inverter.stateThe state of the UPS inverter.string
ups.output.powerThe power output of the UPS.count
ups.bypass.stateThe state of UPS bypass.string
ups.output.load.rateThe rate of UPS output load.percentage
ups.battery.capacityThe capacity of the UPS battery.percentage
ups.battery.positive.voltageThe positive voltage of the UPS battery.count
ups.battery.negative.voltageThe negative voltage of the UPS battery.count
ups.elapsed.time.on.batteryThe elapsed time the UPS has been on battery power.count
ups.charge.remaining.percentThe remaining charge percentage of the UPS battery.percentage
ups.battery.installedIndicates whether the UPS battery is installed.string
ups.output.currentThe current output of the UPS.count
ups.battery.sys.shutdown.durationThe duration of the UPS system shutdown.count
ups.loadThe load on the UPS (Uninterruptible Power Supply).percentage
ups.chargeThe charge level of the UPS battery.percentage
ups.battery.statusThe status of the UPS battery.string
ups.battery.voltageThe voltage of the UPS battery.count
ups.output.load.rateThe rate of UPS output load.percentage
ups.battery.capacityThe capacity of the UPS battery.percentage