Alteon WebSystems Switch, the advanced and high-performance network switch solution by Alteon WebSystems (formerly Radware), seamlessly integrates with Motadata AIOps to provide comprehensive monitoring and management capabilities. With this integration, organizations gain real-time visibility into the performance and health of their Alteon WebSystems Switches. Monitor critical network switch metrics such as port utilization, link status, and packet errors to ensure smooth and efficient network operation.

Prerequisites

Refer Adding network devices for monitoring to understand the prerequisites necessary for monitoring a network device.

List of Supported KPIs

MetricsDescriptionType
ping.min.latency.msMinimum latency (in milliseconds) observed during pingCount
ping.received.packetsNumber of packets received during pingCount
ping.lost.packetsNumber of packets lost during pingCount
ping.max.latency.msMaximum latency (in milliseconds) observed during pingCount
object.targetTarget object identifierString
ping.sent.packetsNumber of packets sent during pingCount
ping.packet.lost.percentPercentage of packet loss during pingPercent
ping.latency.msAverage latency (in milliseconds) observed during pingCount
system.oidSystem Object IdentifierString
started.time.secUptime in Seconds for the monitorCount
started.timeUptime of the monitorString
object.nameName of the monitorString
system.locationLocation of the monitorString
system.descriptionDescription of the monitorString
correlation.metricsCorrelation metrics between network connectionsString
network.connection.tcp.connectionsNumber of TCP connectionsCount
network.connection.udp.connectionsNumber of UDP connectionsCount
network.connection.udp.error.segmentsNumber of UDP error segmentsCount
network.connection.tcp.error.segmentsNumber of TCP error segmentsCount
network.connection.tcp.retransmitted.segmentsNumber of TCP retransmitted segmentsCount
destination.ipDestination IP addressString
destination.portDestination port numberCount
network.connection.protocolProtocol used for network connectionCount
network.connection.stateState of the network connectionString
source.ipSource IP addressString
source.portSource port numberCount
interface.sent.discard.packetsNumber of discarded packets sent on the interfaceCount
interface.in.packetsNumber of incoming packets on the interfaceCount
interface.packetsNumber of packets on the interfaceCount
interface.error.packetsNumber of error packets on the interfaceCount
interface.sent.error.packetsNumber of error packets sent on the interfaceCount
interface.received.discard.packetsNumber of discarded packets received on the interfaceCount
interface.received.octetsNumber of octets received on the interfaceCount
interface.bit.typeBit type of the interfaceCount
statusStatus of the interfaceString
interface.out.packetsNumber of outgoing packets on the interfaceCount
interface.operational.statusOperational status of the interfaceString
interface.admin.statusAdmin status of the interfaceCount
interface.sent.octetsNumber of octets sent on the interfaceCount
interface.last.changeLast change of the interfaceString
interface.received.error.packetsNumber of error packets received on the interfaceCount
interface.discard.packetsNumber of discarded packets on the interfaceCount
started.timeUptime of the interfaceString
started.time.secUptime in seconds of the interfaceString
system.serial.noSerial number of the SNMP device.String
system.hardware.versionHardware version of the SNMP device.String
active.sessionsNumber of active sessions on the SNMP device.Count
http.1.0.connectionsNumber of HTTP 1.0 connections on the SNMP device.Count
http.1.1.connectionsNumber of HTTP 1.1 connections on the SNMP device.Count
http.2.0.connectionsNumber of HTTP 2.0 connections on the SNMP device.Count
http.transactions.per.secHTTP transactions per second on the SNMP device.Count
http.1.1.requestsNumber of HTTP 1.1 requests on the SNMP device.Count
http.1.0.requestsNumber of HTTP 1.0 requests on the SNMP device.Count
power.supply.sensor.statusStatus of the power supply sensor on the SNMP device.String
fan.sensor.statusStatus of the fan sensor on the SNMP device.String
temperature.sensor.statusStatus of the temperature sensor on the SNMP device.String
system.memory.used.percentMemory usage percentage of the SNMP device.Percentage
system.memory.capacity.bytesTotal memory capacity in bytes on the SNMP device.String
system.memory.configured.bytesConfigured memory in bytes on the SNMP device.String
system.switch.processorSwitch processor on the SNMP device.String
system.memory.initial.free.bytesInitial free memory in bytes on the SNMP device.String
system.memory.cached.bytesCached memory in bytes on the SNMP device.String
management.processor.cpu.percentCPU utilization percentage of the management processor.Percentage
management.processor.4sec.avg.cpu.percent4-second average CPU utilization percentage of the management processor.Percentage
management.processor.64sec.avg.cpu.percent64-second average CPU utilization percentage of the management processor.Percentage
management.processor.virtual.memory.bytesVirtual memory in bytes used by the management processor.String
management.processor.resident.memory.bytesResident memory in bytes used by the management processor.String
switch.processor.cpu.percentCPU utilization percentage of the switch processor.Percentage
switch.processor.4sec.avg.cpu.percent4-second average CPU utilization percentage of the switch processor.Percentage
switch.processor.64sec.avg.cpu.percent64-second average CPU utilization percentage of the switch processor.Percentage
vlan.nameThe name of the VLAN.String
vlan.statusThe status of the VLAN.String
vlanThe VLAN identifier.String
vlan.portsThe list of ports associated with the VLAN.String
vlan.portThe specific port associated with the VLAN.String