FG100E_MotaData # config system sflow
FG100E_MotaData (sflow) # set collector-ip 172.16.10.115
FG100E_MotaData (sflow) # set collector-port 4738
FG100E_MotaData (sflow) # end
FG100E_MotaData # config system interface
FG100E_MotaData (interface) # edit wan2
FG100E_MotaData (wan2) # set sflow-sampler enable
FG100E_MotaData (wan2) # set sample-rate 100
FG100E_MotaData (wan2) # set sample-direction both
FG100E_MotaData (wan2) # set polling-interval 60
FG100E_MotaData (wan2) # next
FG100E_MotaData (interface) # end
FG100E_MotaData # cfg save Unknown action 0
To remove configuration.
FG100E\_MotaData # config system sflow
FG100E\_MotaData (sflow) # unset collector-ip
FG100E\_MotaData (sflow) # unset collector-port
FG100E\_MotaData (sflow) # end
FG100E\_MotaData # config system interface
FG100E\_MotaData (interface) # edit wan2
FG100E\_MotaData (wan2) # unset sflow-sampler enable
FG100E\_MotaData (wan2) # unset sample-rate 100
FG100E\_MotaData (wan2) # unset sample-direction both
FG100E\_MotaData (wan2) # unset polling-interval 60
FG100E\_MotaData (wan2) # next
FG100E\_MotaData (interface) # end
FG100E\_MotaData # cfg save