Skip to main content

Configuring Brocade 5600 vRouter

This document provides instructions on configuring the Brocade 5600 vRouter to export v9 flow-monitoring data.

Configuration Steps

Set the UDP collector address:

vyatta@R1# set service flow-monitoring exporter udp-collector address <MOTADATA_NETFLOW_SERVER_IP>

Set the UDP collector port:

vyatta@R1# set service flow-monitoring exporter udp-collector port 2055

Set the flow-monitoring selector:

vyatta@R1# set service flow-monitoring selector s1 randomly out-of 100

Apply the flow-monitoring selector for all interfaces:

vyatta@R1# set interfaces dataplane Interface flow-monitoring selector s1

After completing the configuration, navigate to Menu > Flow Explorer and select the Event Source(s) and the associated Interface(s) from the drop-downs to view the active flow data.